QueueWatchby QueueQuant Price my project Get the plan that holds up best for your site, and where that answer flips.

Generator section unit 48 portmanmoor rd rover way

Rhymney power limited at Cardiff East Grid

NGED Embedded Capacity Register, August 2026 edition

Site, company and substation names are shown as they appear in the registers, including capitalisation.

Date connected
1 Aug 2012
Status
Connected
Customer
Rhymney power limited
Site name
Generator section unit 48 portmanmoor rd rover way
Address
Power Plus Limited Stor Gen, Unit 48, Portmanmoor Road Industrial Estate, Rover Way, Cardiff, South Glamorgan, CF24 5HB
Grid reference
Easting 320621, northing 175688
Licence area
South Wales
Grid supply point
Cardiff East Grid
Bulk supply point
Rover Way Grid
Primary substation
Rover Way Primary
Connection voltage
11 kV
Technology group
Gas and other fossil
Energy source 1
Fossil - Gas, Engine (combustion / reciprocating): 10 MW registered
Registered capacity
10 MW
Maximum export capacity
9.5 MW
Maximum import capacity
0.048 MW
Flexible connection
Not published by NGED
In a connection queue
Not published by NGED
Date accepted
Not stated
Target energisation date
Not stated
Distribution reinforcement reference
Not published by NGED
Transmission reinforcement reference
Not published by NGED
Export MPAN
2100041079809
Import MPAN
2100041079854
Last updated
6 Aug 2026
Tracked since
August 2026 edition

Change history

Tracked since the August 2026 edition, the only one QueueWatch holds so far.

Changes to its status, capacity, technology or customer, newest first.

Changes will show from the next edition.

Also at Cardiff East Grid

GSP view

9 other sites at this grid supply point in the August 2026 edition, 1 of them at Rover Way Primary, the same primary substation. In all, the sites here total 217 MW: 63 MW connected, 154 MW accepted to connect.

See all 9

QueueQuant

Price what a delay would do to your project

QueueWatch reports what changed in the DNOs' published connection registers. It doesn't tell you what to do about it. That's what QueueQuant is for.

Give QueueQuant a site and it compares every way you could power it, on the grid or off it: waiting for the firm date, taking a non-firm offer, building a private wire or going off-grid, across every combination of contracted capacity, generation and battery. That’s millions of possible plans, each tested against thousands of possible futures for delay, curtailment and price. It returns the one plan that holds up best, even when that plan is not to build.

Price my project

Get the plan that holds up best for your site, and where that answer flips.

What you get from QueueQuant

  • The route to power that wins
  • How to size every asset on the site
  • The level of delay or curtailment at which that answer flips
  • Whether the project is worth building at all
  • How bad the worst outcomes get, at the risk level you choose