Distribution / NGED / Grid supply point

Indian Queens Sgp

Grid supply point in South West

NGED Embedded Capacity Register, August 2026 edition

116sites of 1 MW and over
1.5 GWcapacity
0.5 GWconnected (75 sites)
1 GWaccepted to connect (41 sites)

Capacity by technology

TechnologySitesCapacityConnectedAccepted to connect
Solar65704 MW308 MW396 MW
Storage9321 MW–321 MW
Wind26317 MW128 MW189 MW
Gas and other fossil542.1 MW42.1 MW–
Other or not stated837 MW10.1 MW26.9 MW
Bioenergy and waste333.1 MW32.1 MW1 MW

Storage capacity in MWh: not published by NGED.

Each site is grouped by its first energy source, as the register names it.

How busy is each primary substation?

Each primary substation at this grid supply point in the August 2026 edition, under the bulk supply point its register gives. Select a row to see its sites.

Site, company and substation names are shown as they appear in the registers, including capitalisation.

Primary substationBulk supply pointSitesConnectedAccepted to connect
Fraddon Bsp216 MW–
Fraddon Bsp37.8 MW–
Fraddon Bsp14.5 MW–
Fraddon Bsp24 MW–
Fraddon Bsp21 MW2.4 MW
Fraddon Bsp1–1 MW
Fraddon Bsp2299 MW148 MW
Hayle Bsp14.1 MW–
Hayle Bsp13 MW–
Hayle Bsp11.8 MW–
Hayle Bsp11.8 MW–
Hayle Bsp11.1 MW–
Hayle Bsp43 MW132 MW
St Tudy Bsp14.8 MW–
St Tudy Bsp14.1 MW–
St Tudy Bsp13 MW–
St Tudy Bsp12 MW–
St Tudy Bsp11 MW–
St Tudy Bsp1–1 MW
St Tudy Bsp1251 MW40.9 MW
Truro Bsp1–6.5 MW
Truro Bsp25 MW–
Truro Bsp1183.4 MW6.9 MW
St Austell Bsp2–6.4 MW
St Austell Bsp1–4.9 MW
St Austell Bsp1–4.8 MW
St Austell Bsp844.1 MW27.2 MW
Rame Bsp21.7 MW1.8 MW
Rame Bsp1045.7 MW10.5 MW
Camborne Bsp1–1.9 MW
Camborne Bsp417 MW7 MW
Not stated13111 MW531 MW

What changed recently

Changes to the sites here found in both of two consecutive monthly editions, the latest first.

QueueWatch holds one edition of NGED's register so far, the August 2026 edition, so there is nothing to compare yet.

QueueQuant

Price what a delay would do to your project

QueueWatch reports what changed in the DNOs' published connection registers. It doesn't tell you what to do about it. That's what QueueQuant is for.

Give QueueQuant a site and it compares every way you could power it, on the grid or off it: waiting for the firm date, taking a non-firm offer, building a private wire or going off-grid, across every combination of contracted capacity, generation and battery. That’s millions of possible plans, each tested against thousands of possible futures for delay, curtailment and price. It returns the one plan that holds up best, even when that plan is not to build.

Price my project

Get the plan that holds up best for your site, and where that answer flips.

What you get from QueueQuant

  • The route to power that wins
  • How to size every asset on the site
  • The level of delay or curtailment at which that answer flips
  • Whether the project is worth building at all
  • How bad the worst outcomes get, at the risk level you choose

How power reaches a site

A grid supply point (GSP) is where the national grid hands power to the local network. A bulk supply point (BSP) steps it down to a lower voltage for an area. A primary substation steps it down again for the streets and sites nearby. Most small and medium sites connect at a primary. Not every network has all three levels.